Define the load
Provide both source and load water temperatures, seasonal ambient conditions and the required heating or cooling duty.
Temperature Control
Heat and cool aquaculture water through a purpose-designed water-source thermal system.
View image Technical information
Figures below are transcribed from the stated brochure, where available. Confirm the selected model, conditions and scope in the final technical offer.
| Item | Documented information |
|---|---|
| Heat exchanger in company brochure | Titanium tubes / PP shell |
| Operating mode | Heating / cooling |
| Selection inputs | Source and load temperatures, salinity and flow |
Source: 山东纳鑫新能源有限公司.pdf p. 24. Brochure information; final scope is agreed in the technical offer.
Specialist brochure schedule
Quoted figures require the stated operating conditions and final model confirmation.
| Model | Heating capacity (kW) | Heating input (kW) | Cooling capacity (kW) | Cooling input (kW) |
|---|---|---|---|---|
| NXR-80HS | 92 | 18.7 | 81 | 13.7 |
| NXR-120HS | 138 | 27.6 | 121 | 20.6 |
| NXR-160HS | 184 | 37.9 | 162 | 27.5 |
| NXR-200HS | 193 | 38.3 | 170 | 28.9 |
| NXR-240HS | 276 | 55.1 | 242 | 41.2 |
| NXR-300HS | 289 | 57.5 | 256 | 43.4 |
| NXR-400HS | 385 | 76.6 | 341 | 57.8 |
| NXR-500HS | 481.5 | 95.8 | 427 | 72.2 |
| NXR-600HS | 576 | 114.6 | 511 | 86.5 |
| NXR-800HS | 770 | 153.2 | 682 | 115.6 |
Source: 养殖专用海水源热泵机组简介.pdf p. 4 and its English counterpart p. 4. Manufacturer nominal data; no independent test report supplied. Heating: Hot-water outlet 45°C; hot-water flow equals the nominal cooling chilled-water flow; cold-water inlet 15°C; cold-water flow equals the nominal cooling cooling-water flow. Cooling: Chilled-water outlet 7°C; chilled-water flow 0.172 m³/(h·kW); cooling-water inlet 18°C; cooling-water flow 0.103 m³/(h·kW). Conflicting dimensions, connections and weight fields are omitted.
Equipment selection guide
Provide both source and load water temperatures, seasonal ambient conditions and the required heating or cooling duty.
Agree piping or service connections, electrical supply, control interfaces, installation access and the routine cleaning method.
Specify the included equipment, optional configurations, commissioning tasks, acceptance conditions and documentation required.
Operating principle
A refrigerant circuit transfers heat between the source-water side and the load-water side. Source temperature, water flow and required outlet temperature determine the capacity and electrical demand.
Technical approach
Provide the design duty, water or air conditions and seasonal operating points. The technical offer must establish the selected model, available capacity and electrical input at those conditions.
Materials, controls, interfaces and accessories are confirmed in the technical offer. Illustrated equipment and optional functions are not automatically included.
A retrofit review needs the existing hydraulic layout, utilities, available space and operating constraints. Provide photographs and current operating data with your enquiry.
Product brochures
Continue exploring

Temperature Control
Control culture-water temperature where a suitable water heat source is unavailable.

Temperature Control
Extend air-source temperature-control capability to cold-weather aquaculture applications.

Temperature Control
Adjust compressor output to a varying water-temperature-control load.
Start a technical conversation
Share your water flow, temperature duty or cabin requirements so the selected configuration can be discussed.