Define the load
Provide both source and load water temperatures, seasonal ambient conditions and the required heating or cooling duty.
Temperature Control
Extend air-source temperature-control capability to cold-weather aquaculture applications.
View image Technical information
Figures below are transcribed from the stated brochure, where available. Confirm the selected model, conditions and scope in the final technical offer.
| Item | Documented information |
|---|---|
| Required offer data | Capacity and power at the specified low ambient |
| Brochure distinction | Different series quote different ambient limits |
Source: 汇鑫能源科技有限公司.pdf p. 22. Brochure information; final scope is agreed in the technical offer.
Specialist brochure schedule
Series-specific brochure ratings. Final model and design-point performance require confirmation.
| Model | Heating capacity (kW) | Heating input (kW) | Cooling capacity (kW) | Cooling input (kW) |
|---|---|---|---|---|
| NXFR-40C | 38 | 11.2 | 31 | 11.1 |
| NXFR-80C | 77 | 22.8 | 62 | 22.2 |
| NXFR-90C | 84 | 24.4 | 66 | 23.5 |
| NXFR-180C | 168 | 48.9 | 132 | 47.6 |
Source: 养殖专用海水源热泵机组简介.pdf p. 7. Heating: outdoor air 7°C / outlet water 45°C. Cooling: outdoor air 35°C / outlet water 7°C. Electrical supply: 380 V / 3 Ph / 50 Hz. Do not use this nominal point as the winter design-point capacity.
Equipment selection guide
Provide both source and load water temperatures, seasonal ambient conditions and the required heating or cooling duty.
Agree piping or service connections, electrical supply, control interfaces, installation access and the routine cleaning method.
Specify the included equipment, optional configurations, commissioning tasks, acceptance conditions and documentation required.
Operating principle
A low-temperature refrigerant-cycle design, compressor control and defrost strategy support operation at colder ambient conditions than a standard installation.
Technical approach
Provide the design duty, water or air conditions and seasonal operating points. The technical offer must establish the selected model, available capacity and electrical input at those conditions.
Materials, controls, interfaces and accessories are confirmed in the technical offer. Illustrated equipment and optional functions are not automatically included.
A retrofit review needs the existing hydraulic layout, utilities, available space and operating constraints. Provide photographs and current operating data with your enquiry.
Product brochures
Continue exploring

Temperature Control
Heat and cool aquaculture water through a purpose-designed water-source thermal system.

Temperature Control
Control culture-water temperature where a suitable water heat source is unavailable.

Temperature Control
Adjust compressor output to a varying water-temperature-control load.
Start a technical conversation
Share your water flow, temperature duty or cabin requirements so the selected configuration can be discussed.